Retained guide wire fragment causing hemothorax
Cite this case
[...]. Retained guide wire fragment causing hemothorax. CTICases. Published July 11, 2019. https://str-case-explorer.pages.dev/c/36x6d
Imaging findings
Radiograph and CT show a long guide wire fragment in the brachiocephalic vein extending into the IVC, left behind during a line placement 9 years prior, complicated by hemothorax.
Key takeaways
Retained guide wires are rare iatrogenic complications of central venous catheterization. They can remain asymptomatic for years before migrating and causing vascular perforation, thrombosis, or hemothorax.
AI-assisted summary — may contain errors. Verify against the source video. Learn more
More from this webinar
- Proximal interruption of the left pulmonary artery with right aortic archPulmonary Vascular
- Isolated pulmonary artery with ductal origin and pulmonary hypertensionPulmonary Vascular
- Surgically repaired proximal interruption of the right pulmonary arteryPulmonary Vascular
- Coronary peri-arteritis in IgG4-related systemic diseaseCoronary
- Pulmonary Tuberculosis in a liver transplant recipientInfection
- Intracardiac foreign body (sewing needle in the heart)Devices & Post-op
- Pseudo-coarctation of the aortaAorta & Arteries
- Iatrogenic chylothorax post-thyroidectomyIatrogenic