Imaging findings
Three metallic mitral clips are visualized, located at the mitral valve. Mitral annulus calcification is also noted. The clips are discernible on both CT and radiography.
Key takeaways
This case serves as a clear example of mitral clips, devices used to manage mitral valve incompetence. In this patient, three clips were deployed due to insufficient reduction of regurgitation with initial clips, highlighting the potential for multiple device placements and the possibility of suboptimal functional outcomes despite implantation.
AI-assisted summary — may contain errors. Verify against the source video. Learn more
More from this webinar
- Intrapulmonary Bronchogenic Cyst (with Hemorrhage/Infection)Congenital
- Thymic CarcinoidNeoplastic
- Necrotizing Pneumonia (Group A Streptococcus) and Pneumocystis PneumoniaInfection
- Atrio-esophageal Fistula with Pneumopericardium Post-Left Atrial AblationPericardial
- Anti-Synthetase Syndrome (Anti-Jo-1) with Organizing PneumoniaILD
- Iatrogenic Air EmbolismIatrogenic
- Combined Partial Anomalous Pulmonary Venous Return and Congenital Bronchial AtresiaCongenital
- CoccidioidomycosisInfection
See all cases from September 24, 2015 →
Related Valvular cases
- Carcinoid Heart Disease
- Transcatheter Aortic Valve Replacement (TAVR) / CoreValve Prosthesis in Failing Bioprosthetic Aortic Valve
- Severe Left Atrial Wall Thickening (Rheumatic Heart Disease)
- Valve-in-Valve TAVR for Paravalvular Leak
- Giant Left Atrial Aneurysm
- Systolic Anterior Motion (SAM) of the Mitral Valve without Hypertrophic Cardiomyopathy