Bioabsorbable Hemostatic Packing Material (Surgicel) Mimicking a Mass After Aortic Surgery
[...]. Bioabsorbable Hemostatic Packing Material (Surgicel) Mimicking a Mass After Aortic Surgery. CTICases. Published June 15, 2018. https://str-case-explorer.pages.dev/c/dpsdc
Imaging findings
A patient status post aortic surgery had postoperative imaging showing a gas-containing, somewhat mass-like collection at the operative site; a follow-up study roughly six weeks later showed the finding had completely resolved, consistent with resorption of bioabsorbable cellulose-based hemostatic packing material (Surgicel or similar) that had been placed intraoperatively to control bleeding.
Key takeaways
Bioabsorbable hemostatic packing materials such as Surgicel can appear mass-like and gas-containing on early postoperative imaging, mimicking an abscess, retained foreign body, or tumor, but they resorb over a period of weeks; recognizing this expected postoperative appearance and its trajectory of resolution prevents unnecessary concern or intervention.
AI-assisted summary — may contain errors. Verify against the source video. Learn more
More from this webinar
- Mixed Fungal Infection with Mucormycosis "Bird's Nest" Sign, Aspergillus Abscess, and CandidaInfection
- Donor-Derived Respiratory Bronchiolitis After Single Lung TransplantILD
- Synchronous Adenocarcinoma, Carcinoid Tumor, and Pulmonary Langerhans Cell Histiocytosis in the Same LobeNeoplastic
- Pleural Tuberculosis Mimicking Malignant Pleural Spread over Several YearsInfection
- Localized (Unilobar) Allergic Bronchopulmonary AspergillosisInflammatory
- Acute Eosinophilic Pneumonia of Undetermined CauseILD
- Hypersensitivity Pneumonitis Demonstrated by the "Gray Lung" Window/Level SignILD
- Intrathoracic (Mediastinal) Ectopic Thyroid Tissue Displacing the TracheaOther
See all cases from June 15, 2018 →
Related Devices & Post-op cases
- Multiple Malpositioned Cardiac Resynchronization Therapy Leads, Including Right Ventricular Perforation
- Atrioesophageal Fistula After Atrial Fibrillation Ablation with Embolic Strokes
- Left Ventricular Pseudoaneurysm after Cardiac Surgery
- Amplatzer Amulet Left Atrial Appendage Occlusion Device
- LVAD Outflow Graft Extraluminal Debris Causing Low-Flow Alarms
- Intrapericardial Sternal Wire Migration