Retained 7-0 Prolene Surgical Suture Needle
[...]. Retained 7-0 Prolene Surgical Suture Needle. CTICases. Published March 31, 2017. https://str-case-explorer.pages.dev/c/eknqx
Imaging findings
Post-operative chest radiograph following aortic valve replacement reveals a tiny, subtle metallic foreign body in the mediastinum, corresponding to a 7-0 Prolene suture needle. The surgical team successfully identified the needle's presence and exact location on the chest radiograph with the assistance of a reference specimen image provided by the radiology department.
Key takeaways
Radiographic detection of tiny surgical needles (such as 7-0 Prolene needles) can be exceptionally challenging. Providing an intraoperative reference radiograph of the exact needle type being searched for is an effective clinical workflow that aids radiologists in spotting extremely small retained foreign bodies before chest closure or during immediate re-exploration.
AI-assisted summary — may contain errors. Verify against the source video. Learn more
More from this webinar
- Pulmonary Atresia with Intact Ventricular Septum and Right Ventricular Dependent Coronary CirculationCongenital
- High-Flow Mediastinal Vascular Malformation (Azygos to Left Atrial Communication)Congenital
- Primary Tracheal Squamous Cell CarcinomaNeoplastic
- Unroofed Coronary Sinus with Anomalous Pulmonary Venous ReturnCongenital
- Circumflex Right Aortic ArchAorta & Arteries
- Focal Aortic Root Dissection in Systemic Lupus ErythematosusAorta & Arteries
- Mounier-Kuhn Syndrome (Tracheobronchomegaly)Congenital
- Bronchial Diverticulum Mimicking Anastomotic Airway InjuryArtifact
See all cases from March 31, 2017 →
Related Devices & Post-op cases
- Amplatzer Plug for Post-Myocardial Infarction Ventricular Septal Defect
- Watchman Left Atrial Appendage Occlusion Device
- Outflow Cannula Obstruction of a HeartMate II Left Ventricular Assist Device (LVAD) Treated with Stenting
- HeartMate II LVAD Outflow Cannula Infection and Debris Accumulation
- Dislodged Atrial Septal Defect (ASD) Occluder Device
- Impella-Induced Defibrillator Lead Displacement