Aortic Flow mixing (Smoke) Artifact
[...]. Aortic Flow mixing (Smoke) Artifact. CTICases. Published April 28, 2017. https://str-case-explorer.pages.dev/c/fz8rn
Imaging findings
Contrast-enhanced CT angiogram shows a prominent, horizontal, low-attenuation band of poor contrast mixing (or "smoke" artifact) in the transverse aortic arch and proximal descending thoracic aorta. A repeat CT angiogram obtained with a slightly delayed arterial phase demonstrates complete resolution of the low-attenuation band with normal, homogeneous opacification of the aorta.
Key takeaways
Slower blood flow along the inner curvature (undersurface) of the aortic arch can cause transient contrast-mixing artifacts that mimic acute aortic dissection on early-phase, rapid-pitch helical acquisitions. This phenomenon of slower flow also explains why aortic thrombi preferentially develop in this specific location.
AI-assisted summary — may contain errors. Verify against the source video. Learn more
More from this webinar
- Myocarditis Evaluated with Dual-Energy CTMyocarditis
- Mediastinal Liposarcoma with Right Heart CompressionNeoplastic
- Erdheim-Chester DiseaseMasses
- Amiodarone-Induced Systemic DepositionArtifact
- Granulomatosis with Polyangiitis with Pituitary InvolvementAutoimmune
- HIV-Associated Myocarditis with Left Ventricular ThrombusMyocarditis
- Low-Positioned Intra-Aortic Balloon Pump causing Mesenteric IschemiaDevices & Post-op
- Coal Workers' PneumoconiosisExposure
See all cases from April 28, 2017 →
Related Aorta & Arteries cases
- Intramural Hematoma of the Ascending Aorta with Evolution to an Ulcer-Like Projection
- Acute Aortic Intramural Hematoma with Intimal-Medial Breach
- Subclavian Artery Thrombosis due to Anomalous First Rib
- Ruptured Type B Aortic Dissection and Bilateral Partial Anomalous Pulmonary Venous Return
- Penetrating Aortic Injury from a Nail Gun
- Circumflex Right Aortic Arch