Aortic Graft Dehiscence and Coronary Napkin Ring Sign
[...]. Aortic Graft Dehiscence and Coronary Napkin Ring Sign. CTICases. Published January 13, 2017. https://str-case-explorer.pages.dev/c/n2w36
Imaging findings
CT angiography shows dramatic dehiscence and rupture of an ascending aortic graft with extensive surrounding mediastinal hemorrhage extending intrapericardially and epicardially. Within the coronary circulation, there is a clear napkin ring sign in a coronary artery plaque, characterized by a low-attenuation necrotic core surrounded by a higher-attenuation rim of tissue.
Key takeaways
Aortic graft dehiscence is a catastrophic complication of surgical replacement that presents with significant perigraft and mediastinal leakage. In the coronary arteries, the napkin ring sign is a specific imaging feature of a highly vulnerable plaque with a large lipid-rich necrotic core and a thin fibrous cap, a key marker of high cardiovascular risk under the CAD-RADS reporting system.
AI-assisted summary — may contain errors. Verify against the source video. Learn more
More from this webinar
- Right Ventricular Outflow Tract Fistula and RCA Epicardial Hemorrhage post-TAVRValvular
- Lipomatous Hypertrophy of the Interatrial SeptumMasses
- Edwards INTUITY Elite Rapid-Deployment Bioprosthetic Aortic ValveValvular
- Alveolar Pulmonary Edema due to OverhydrationVascular
- Tuberculous Aortic Root EndocarditisValvular
- Bioprosthetic Mitral Valve EndocarditisValvular
- Pulmonary Arteriovenous Malformation in Hereditary Hemorrhagic TelangiectasiaCongenital
- Rib HemangiomaNeoplastic
See all cases from January 13, 2017 →
Related Aorta & Arteries cases
- Sinus of Valsalva Aneurysm with Bicuspid Aortic Valve and Coarctation of the Aorta
- Sarcoid Aortitis
- Presumed Takayasu Arteritis (Extensive Aortic Vasculitis)
- Aortic Pseudo-Dissection Artifact from Pneumomediastinum and Cardiac Pulsation
- Aortoesophageal Fistula Post-TEVAR Due to Stent Infection
- Coarctation of the Aorta with Classic '3 Sign'