Imaging findings
Cardiac 4D flow MRI in two young patients with bicuspid aortic valves demonstrates different flow profiles in the ascending aorta. The first patient shows an off-center, eccentric, helical jet of flow during systole that directly impacts the lateral aortic wall, creating high wall shear stress and local eddy currents. The second patient demonstrates a more centered, laminar flow pattern with evenly distributed forces.
Key takeaways
4D flow cardiac MRI can visualize and quantify altered flow hemodynamics and wall shear stress in patients with bicuspid aortic valves. Eccentric, off-center systolic jets are associated with increased localized wall shear stress, which predisposes patients to asymmetric aortic dilation and aneurysm formation, whereas laminar flow patterns distribute forces more evenly and are less prone to rapid dilation.
AI-assisted summary — may contain errors. Verify against the source video. Learn more
More from this webinar
- Giant Cell ArteritisAorta & Arteries
- Mycotic Pseudoaneurysm of the Ascending Aorta Treated with EndoAnchorsAorta & Arteries
- Chronic Aortic Dissection with Multiple Small FenestrationsAorta & Arteries
- Type A Aortic Dissection with Large Intramural HematomaAorta & Arteries
- Intravenous Metallic Mercury EmbolizationExposure
- Burned-out Langerhans Cell HistiocytosisILD
- Diaphragmatic EventrationCongenital
- Giant Sinus of Valsalva AneurysmAorta & Arteries
See all cases from June 30, 2017 →
Related Valvular cases
- Traumatic Papillary Muscle Rupture
- Subaortic Membrane
- Hemopericardium and Tamponade after Transcatheter Aortic Valve Replacement (TAVR)
- Melody Valve Thrombosis
- Transcatheter Aortic Valve Replacement (TAVR) Leaflet Thrombosis with Restricted Motion
- Left Ventricular Outflow Tract Obstruction by Mitral Valve Bioprosthesis