Axillary Impella Insertion Site Pseudoaneurysm
[...]. Axillary Impella Insertion Site Pseudoaneurysm. CTICases. Published February 12, 2022. https://str-case-explorer.pages.dev/c/z9zm8
Imaging findings
Contrast-enhanced CT of the chest and upper extremity shows a lobulated, enhancing pseudoaneurysm arising from the right axillary artery at the insertion site of a recently removed Impella mechanical circulatory support device, accompanied by surrounding soft tissue hematoma.
Key takeaways
Pseudoaneurysms are a known vascular complication at the arteriotomy site of large-bore sheaths used for devices like the Impella. Direct inspection of the access site on CT is indicated when patients present with a post-procedure drop in hematocrit, localized pain, or a pulsatile mass.
AI-assisted summary — may contain errors. Verify against the source video. Learn more
More from this webinar
- Tuberous SclerosisCongenital
- Corduroy Artifact in Digital RadiographyDevices & Post-op
- Cystic Lung Disease in Chronic Lymphocytic LeukemiaNeoplastic
- EVALIExposure
- Fibrotic Hypersensitivity PneumonitisExposure
- Sinus Venosus ASD with PAPVRCongenital
- Adenocarcinoma with Lymphangitic CarcinomatosisNeoplastic
- Blastomycosis Osteomyelitis of the TibiaInfection
See all cases from February 12, 2022 →
Related Aorta & Arteries cases
- Abdominal Aortic Stenosis in Neurofibromatosis Type 1
- Aortic Root Pseudoaneurysm Erosion into Left Atrium
- Aortoesophageal Fistula secondary to Mycotic Aortic Aneurysm
- Aortic Dissection with Intimal Intussusception
- Aortic Coarctation with Unilateral Collateral Arteries
- Type A Aortic Dissection on CT Pulmonary Angiography